Ventilation design
High extraction >> Tunnel

BROILER:
BREEDING:
LAYING:
TEMPERATE ZONE
Width
15 to 28 m in temperate zones
12 to 20 m in arid zones
Length
70 to 120 m in 2 zones
Temperate zone
40 to 150 m in 3 zones
Arid zone
Side Height
2 to 3 m
Roof slope
25 to 30%
Temperate zone
0 to 30%
Arid zone
BENEFITS
- Easier control (cold air more easily directed upwards)
- Air flow velocity controlled across the poultry right up to the plumage
- Homogeneous temperatures, bedding and aeration for poultry
- Gradual and tailored transition (gradual engagement of gable positioned turbines in addition to chimney shafts)
- Gradual increase in longitudinal air speed (depending on the number of extractors used on the gable)
- Tunnel effect for cooling poultry at the end of a batch or when outside temperatures are high
- Can be combined with Cooling or HP misting (if the climate is not humid)